Near-field probes are used for performing measurements of high-frequency electric and magnetic RF fields on assemblies and devices. Technical parameters for single probes can be found in the respective product articles and in the downloadable overview PDF.
<br>
Model | Category | Frequency Range | Probe head dimensions | Connector |
---|---|---|---|---|
RF1 set | Near-Field Probes | 30 MHz - 3 GHz | SMB, male, jack | |
RF2 set | Near-Field Probes | 30 MHz - 3 GHz | SMB, male, jack | |
RF3 mini set | Near-Field Probes | 30 MHz - 3 GHz | SMB, male, jack | |
RF4-E set | Near-Field Probes E-field | 30 MHz - 3 GHz | SMB, male, jack | |
RF-R 400-1 | H-Field Probe | 30 MHz - 3 GHz | Ø ≈ 25 mm | SMB, male, jack |
RF-R 50-1 | H-Field Probe | 30 MHz - 3 GHz | Ø ≈ 10 mm | SMB, male, jack |
RF-R 3-2 | H-Field Probe | 30 MHz - 3 GHz | Ø ≈ 3 mm | SMB, male, jack |
RF-R 0.3-3 | H-Field Probe mini | 30 MHz - 3 GHz | Ø ≈ 2 mm | SMB, male, jack |
RF-B 50-1 | H-Field Probe | 30 MHz - 3 GHz | Ø ≈ 10 mm | SMB, male, jack |
RF-B 3-2 | H-Field Probe | 30 MHz - 3 GHz | Ø ≈ 4 mm | SMB, male, jack |
RF-B 0.3-3 | H-Field Probe mini | 30 MHz - 3 GHz | Ø ≈ 2 mm | SMB, male, jack |
RF-U 5-2 | H-Field Probe | 30 MHz - 3 GHz | ≈ (6 x 6) mm | SMB, male, jack |
RF-U 2.5-2 | H-Field Probe | 30 MHz - 3 GHz | Ø ≈ 4 mm | SMB, male, jack |
RF-K 7-4 | H-Field Probe | 30 MHz - 1 GHz | ≈ (6 x 10) mm | SMB, male, jack |
RF-E 02 | E-Field Probe | 30 MHz - 1.5 GHz | ≈ (23 x 53) mm | SMB, male, jack |
RF-E 03 | E-Field Probe | 30 MHz - 3 GHz | ≈ (4 x 4) mm | SMB, male, jack |
RF-E 04 | E-Field Probe | 30 MHz - 3 GHz | ≈ (5 x 5) mm | SMB, male, jack |
RF-E 05 | E-Field Probe | 30 MHz - 3 GHz | ≈ (1 x 8) mm | SMB, male, jack |
RF-E 09 | E-Field Probe | 30 MHz - 3 GHz | ≈ (10 x 10) mm | SMB, male, jack |
RF-E 10 | E-Field Probe | 30 MHz - 3 GHz | ≈ (0.5 x 2) mm | SMB, male, jack |
Model | Category | Frequency Range | Resolution | Connector |
---|---|---|---|---|
MFA 01 set | Micro Probes | 1 MHz - 6 GHz | 200 µm | |
MFA 02 set | Micro Probes | 1 MHz - 1 GHz | 200 µm | |
MFA-R 0.2-6 | Near-Field Micro Probe | 100 MHz - 6 GHz | 300 µm | SMA, female, jack |
MFA-R 0.2-75 | Near-Field Micro Probe | 1 MHz - 1 GHz | 300 µm | SMA, female, jack |
MFA-K 0.1-12 | Near-Field Micro Probe | 100 MHz - 6 GHz | 200 µm | SMA, female, jack |
MFA-K 0.1-30 | Near-Field Micro Probe | 1 MHz - 1 GHz | 200 µm | SMA, female, jack |
Model | Category | Frequency Range | Probe head dimensions | Connector |
---|---|---|---|---|
XF1 set | Near-Field Probes | 30 MHz - 6 GHz | SMA, male, jack | |
XF-R 400-1 | H-Field Probe | 30 MHz - 6 GHz | Ø ≈ 25 mm | SMA, female, jack |
XF-R 100-1 | H-Field Probe | 30 MHz - 6 GHz | ≈ (10x10) mm | SMA, female, jack |
XF-R 3-1 | H-Field Probe | 30 MHz - 6 GHz | Ø ≈ 3 mm | SMA, female, jack |
XF-B 3-1 | H-Field Probe | 30 MHz - 6 GHz | Ø ≈ 4 mm | SMA, female, jack |
XF-U 2.5-1 | H-Field Probe | 30 MHz - 6 GHz | Ø ≈ 4 mm | SMA, female, jack |
XF-E 04s | E-Field Probe | 30 MHz - 6 GHz | ≈ (5 x 5) mm | SMA, female, jack |
XF-E 09s | E-Field Probe | 30 MHz - 6 GHz | ≈ (10 x 10) mm | SMA, female, jack |
XF-E 10 | E-Field Probe | 30 MHz - 6 GHz | ≈ (0.5 x 2) mm | SMA, female, jack |
Model | Category | Frequency Range | Probe head dimensions | Connector |
---|---|---|---|---|
LF1 set | Near-Field Probes | 100 kHz - 50 MHz | SMB, male, jack | |
LF-R 400 | H-Field Probe | 100 kHz - 50 MHz | Ø 25 mm | SMB, male, jack |
LF-R 50 | H-Field Probe | 100 kHz - 50 MHz | Ø ≈ 10 mm | SMB, male, jack |
LF-R 3 | H-Field Probe | 100 kHz - 50 MHz | Ø ≈ 3 mm | SMB, male, jack |
LF-B 3 | H-Field Probe | 100 kHz - 50 MHz | Ø ≈ 4 mm | SMB, male, jack |
LF-U 5 | H-Field Probe | 100 kHz - 50 MHz | ≈ (6 x 6) mm | SMB, male, jack |
LF-U 2.5 | H-Field Probe | 100 kHz - 50 MHz | Ø ≈ 4 mm | SMB, male, jack |
LF-K 7 | H-Field Probe | 100 kHz - 50 MHz | ≈ (6 x 10) mm | SMB, male, jack |
Model | Category | Frequency Range | Probe head dimensions | Connector |
---|---|---|---|---|
SX1 set | Near-Field Probes | 1 GHz to 10 GHz | SMA, female, jack | |
SX-R 20-1 set | Near-Field Probe | 1 GHz to 20 GHz | ≈ 6x6 mm | SMA, female, jack |
SX-R 3-1 | H-Field Probe | 1 GHz to 10 GHz | Ø ≈ 3 mm | SMA, female, jack |
SX-R 20-1 | H-Field Probe | 1 GHz to 20 GHz | ≈ 6x6 mm | SMA, female, jack |
SX-B 3-1 | H-Field Probe | 1 GHz to 10 GHz | Ø ≈ 4 mm | SMA, female, jack |
SX-E 03 | E-Field Probe | 1 GHz to 10 GHz | ≈ (4 x 4) mm | SMA, female, jack |
Model | Category | Frequency Range | Connector |
---|---|---|---|
HR1 set | Near-Field Probes | up to 40 GHz | 2.92 mm (K), female, jack |
HR-R 8-1 set | Near-Field Probe Set | up to 40 GHz B-field | 2.92 mm (K), female, jack |
HR-R 8-1 | Near-field probe | up to 40 GHz B-field | 2.92 mm (K), female, jack |
HR-E 40-1 set | Near-Field Probe Set | up to 40 GHz E-field | 2.92 mm (K), female, jack |
HR-E 40-1 | E-Field Probe | up to 40 GHz | 2.92 mm (K), female, jack |